<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-10 01-41-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 68 dBuV Classic
Pilot RDS Phase Difference
6.7 kHz 2.7 kHz -14 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 65 kHz 19079 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 1,58 dBr 3,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Valssi nro 5 E-duuri (Brahms) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 65 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/03/10 1.40.16 Total samples: 19079 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,0 dBr MIN: 0,5 dBr AVE: 1,58 dBr % above 12,2 dBr: 0,0 Last value: 2,2 dBr (2025/03/10 1.40.16) 01.26 01.28 01.30 01.32 01.34 01.36 01.38 01.40 -1 0 1 2 3 4 Pm [dBr]